“Biopotential Electrodes.” The Biomedical Engineering Handbook: Second Edition. Bronzino Boca Raton: CRC Press LLC, 2000. Strain Gage: Materials material gage factor, G TCR (10-5) Ni80 Cr20 2.1 - 2.6 10 Pt92 W8 3.6 – 4.4 24 Silicon (n type) -100 to -140 70 to 700Germanium (p type) 102TCR = temperature coefficient of resistivity (ºC-1). Note:. G for semiconductor materials 50-70 x that of metals. Electronics by Professor Peter Y. This note describes the following topics: Basic electrical signals, circuits and systems, digital basics, Signals and Measurements, Resistor Circuits, Nodal Analysis, Thevenin Equivalent Circuits, Capacitors and Inductors, Thevenin Equivalent Circuits, Capacitors and Inductors, Frequency Response, Transient Response and Impedances, Amplification. The editors are very grateful to all the medical professionals from Jimma, Hawassa, and Haramaya Universities, who have contributed in different ways to help develop this lecture note. Our special thanks go to the contributing authors, who took time from their very tight schedules, to prepare the draft lecture notes, in different topics.

---------------------
4.9

Here you can download the free lecture Notes of Biomedical Instrumentation Pdf Notes (BI Notes Pdf) materials with multiple file links to download. Biomedical Instrumentation Notes Pdf book starts with the topics covering Internise characteristics of MEMS, energy domain,sensors and actuators, introduction to fabrication, silicon based mems process, new materials, review of electrical and mechanical concepts of MEMS, semi conductor devices, stress and strain analysis, etc.

Download Biomedical Instrumentation Pdf Notes – BI Notes Pdf file

Biomedical Instrumentation Pdf Notes – BI Notes Pdf file to download are listed below please check it

BI Complete Notes

1st Unit Notes

2nd Unit Notes

3rd Unit Notes

4th Unit Notes

Note: These notes are according to the R09 Syllabus book of JNTU. In R13 and R15, 8-units of R09 syllabus are combined into 5-units in R13 and R15 syllabus. If you have any doubts please refer to the JNTU Syllabus Book.

Biomedical Instrumentation Pdf Books Material topics

Unit-1: Biomedical Instrumentation Pdf Notes – BI Notes Pdf

Internise characteristics of MEMS, energy domain,sensors and actuators, introduction to fabrication, silicon based mems process, new materials, review of electrical and mechanical concepts of MEMS, semi conductor devices, stress and strain analysis, flexural beam binding,torsional deflection, micro electrical mechanical systems, merits of Mems devices and microfabrication technologies, micro eloctronics integration, parllel fabrication with high precision explain the intrinsic characteristics of MEMS, miniaturization, scaling law,nano electromechanical system, micro eloctronic integration, mechanical electrical domain, chemical electrical transduction. sensor consideration,physical sensor, biological sensor, linearity, accuracy, precision, noise, actuators.

Unit-2: Biomedical Instrumentation Pdf Notes – BI Notes Pdf

Transuducer,sensor,actuator,electrostatic sensors,parllel plate capacitor,applications,inter digit finger capacitance,applications of comb drives,inertia sensor,comb drive accelerometer,micro grippers and micro meters,thermal sensing and actuation,thermal conduction,natural conduction,forced thermal conduction,radiations,mechanical,thermal,chemical,bio sensors,radiation,magnetic,physical input,physical output,mechanical thermal chemical radiantelectrical magnetic,sensor,modifier,actuator,input and output sensors,major input,major output.

Unit-3: Biomedical Instrumentation Pdf Notes – BI Notes Pdf

sensor and actuators, piezo resistive sensors, piezo resistive sensor materials, stress analysis of mechanical elements, applications of inertia. Pressure tactile and flow sensors, piezo electric sensors and actuators, piezo electric effects. piezo electric materilas, applictaion of inertia,tactile and flow sensors, multi axis piezo resistive sensors, method for analysing the magnitude of stress any where in a cantilever beam under simple transverse force loading conditions,procedure for analyzing relative resistances changes under simple loading on a constilever, the influence of temperature on silicon piezo resistor on the factors,identification of relative magnitude and signs of stress in different regions of a memberence under uniform pressure loading.

Unit-4: Biomedical Instrumentation Pdf Notes – BI Notes Pdf

Micro machanism, avisotropic etching, rules of anistropic etching, silicon anistropic etching, rules of anistropic etching, iso tropic wet etching, gas phase etchants,native oxide, special water and techniques, electro chemical etch stop layer. basic surface micro machning process,sacrifical etching process,micro motor fabrication process,acceleraton of sacrificiacl etch,the basic two layer surface micromachning process,the use of micromachningprocess for realizing micrometer.

FAQs:

Q1: What is Biomedical Instrumentation?

Basic Electronics Notes

A1: Biomedical instrumentation is the application of knowledge and technologies to solve problems related to living biological systems. It involves diagnosis, treatment and prevention of disease in human. The term “bio” is to denote something related to life.

Q2: What does Biomedical Instrumentation involves?

A2: It involves measurement of biological signals like ECG, EMG, or any electrical signals generated in the human body. To diagnose the problem and to provide treatment Biomedical Instrumentation helps physicians. Concepts of electronics and measurement techniques are needed To measure biological signals and to design a medical instrument.

Q3: What is the scope of Biomedical Instrumentation?

A3: As the medical field is emerging, the area of Biomedical Instrumentation is an expanding field. The drastic advancement of technology involved in biomedical engineering will carry on changing the job profile of biomedical engineers. It will also carry on creating new work areas. Hence, there is a need to convert the expanding range of activities for biomedical engineers into very favorable job prospects. The retirement of a substantial count and fast aging of the population of biomedical engineers is possible to result in huge job openings between the period of 2019 and 2024.

Employment of biomedical engineers is expected to grow at seven per cent from 2016 to 2026. As the aging baby-boom generation stays active and lives longer, the demand for biomedical procedures and devices is expected to increase. Several opportunities exist for students pursuing a course in biomedical sciences in India. It is a huge, happening subject with huge opportunities for management, laboratory work, education, research, and consultancy. Once you become competent in the subject, you can work in the private sector or the numerous national healthcare laboratories. Those who do not find themselves appropriate for standard hospital careers may choose for health protection agencies, or work in forensic science departments. Job profile include:

Medical Electronics Notes Pdf
  • Instrument engineer
  • Bio medical engineer
  • Researcher
  • Installation engineer
  • Maintenance engineer

Follow us on Facebook and Support us with your Like

How useful was this post?

Click on a star to rate it!

Average rating 4.9 / 5. Vote count: 28

No votes so far! Be the first to rate this post.

Pdf notes downloadAnti-Sleep Alarm - Most of the accidents on highways during night occur due to drivers’ poor vision caused by the continuous exposure of their eyes to the bright light from the headlamps of approaching...__ Electronics Projects for You

Antisleep Alarm for Students - This circuit saves both time and electricity for students. It helps to prevent them from dozing off while studying, by sounding a beep at a fixed time interval, say, 30 minutes....__ Electronics Projects for You

Bed Wetting Alert - Keep the tide out with this effective bed wetting alarm. You just add some circuitry to Jaycar's 'Secret Farter' and make a sensor.__ SiliconChip

Bedwetting/Wet Diaper Alert SystE - M - Bedwetting is one of the most common childhood problems that can have a significant impact on a child’s health if left unattended. During the night, the parents would not know if the child has urinated and the kid may sleep all night long on a wet bed, or with a wet nappy. Bedwetting/Wet Nappy alert system provides a very __ Designed by T.K. Hareendran

Body Weight Scale Reference Design with Body Composition capability and BLE Connectivity - This reference design is for a complete body weight scale end equipment with body composition capability featuring TI signal chain, power, and connectivity components. With TI’s AFE4300 weigh scale/body composition AFE, you can accelerate your body weight scale design or quickly add body composition measurement features to your existing platform. This reference design also includes the full BLE connectivity design for easy interface to BLE enabled smartphones, tablets, etc__ Texas Instruments

Booze Buster Breath Tester - Use this fun device to test your soberity, err sobrity, err how much you have had to drink but dont rely on it to drive.__ SiliconChip

Ec8073 Medical Electronics Notes Pdf

Brain Wave Machine - Humans have been using light and sound to achieve altered states of consciousness for thousands of years. Primitive cultures used flickering fires and rythmic drumming to induce these altered states. Today, you can choose from a wide variety of electronic brain-wave machines which use light and/or sound to alter brain-wave activity. Brain-wave activity ranges from fully awake to deep dreamless sleep. This activity is categorized into five primary groups: Delta, Theta, Alpha, Beta, and Gamma. __ Designed by © Hack Canada

Electronics

CC2541 Keyfob Reference Design - The Bluetooth Smart Keyfob is a small-form factor, coin-cell powered mobile accessory with buttons, buzzer, LEDs and accelerometer, demonstrating the use of several of the BLE GATT service profiles, like the proximity and battery service profiles.__ Texas Instruments

Circuit Monitors Power Loss - For some medical equipment it is important for an operator to know when power is lost to the machine. The beeper is powered from a 9v battery and requires the machine to have a power switch with a third set of contacts . . . Hobby Circuit designed by David Johnson P.E.-March, 1999

Convert your smartphone into a pedometer & tracking Device - EDN-Design Ideas 10/22/12 When you go hiking or mountain biking, or simply take a long walk around the neighborhood, you might wonder about the distance you covered or specific details, such as speed. A specialized device for such a task is an expensive idea. Now, however, the increasing penetration of smartphones in the market with built-in GPS devices makes it possible to configure a mobile phone to log or send the current readings from its sensors to a server for viewing and processing. This design idea describes a simple approach to log readings from a GPS using the Python scripting language. An advantage of Python is that an electronics engineer need not delve into the complex realm of C/C++ calls for Symbian/Android architectures to accomplish this simple task. All that is required is the installation on a phone of the Python interpreter, along with a text file containing the script. __ Circuit Design by Ali Asgher Mansoor Habiby and Abdus Sami Abdul Qayyum, Sir Syed University, Karachi, Pakistan

Corona Monitor - The circuit is powered by +5v and has an on-board voltage regulator as a reference voltage. The current from a reversed biased photodiode is converted into a voltage using an op amp circuit. That output voltage is fed to a voltage comparator circuit. Included is an adjustment in the current to voltage converter, to calibrate the installed circuit . . . Dave Johnson, Lubbock TX (Mar 30, 2010)-DC Magazine - Issue 8 Apr 2010

Cranial Electrical Stimulation Unit - Commercial cranial electrical stimulation (CES) units cost hundreds of dollars but this one is cheap and easy to build. It is battery-powered, portable and has adjustable current delivery and repetition rate.__ SiliconChip

Cranial Electrotherapy Stimulation (CES) - IC1 forms a narrow pulse, 2.5Hz oscillator feeding IC2. This chip generates the various timings for the output pulses. Output is taken at pins 2 & 3 to easily obtain negative going pulses also. Current output is limited to 600µA by R2 and can be regulated from 80 to 600µA by means of R3. The LED flashes every 2 seconds signaling proper operation and can also be used for setting purposes. It can be omitted together with R4, greatly increasing battery life. __ Designed by © Hack Canada

Cranial Electrotherapy Stimulator - Current flows through clips placed on the earlobes; Output current adjustable from 80 to 600 microAmperes __ Contact: Flavio Dellepiane, fladello @ tin.it

Digital pedometer - Medical and health related electronic circuit diagrams / circuit schematics

Digital pedometer - Pedometer has a range of 9.950 meters with2-digits. Slip it in pants pocket for walking and jogging __ Contact: Flavio Dellepiane, fladello @ tin.it

Digital Step-Km Counter-Max. Range: 9,950 meters - This circuit measures the distance covered during a walk. Hardware is located in a small box slipped in pants' pocket and the display is conceived in the following manner: the leftmost display D2 (the most significant digit) shows 0 to 9 Km. and its dot is always on to separate Km. from hm. The rightmost display D1 (the least significant digit) shows hundreds meters and its dot illuminates after every 50 meters of walking.__ Learning Electronics

DIY ECG Patient Simulator / ECG Tester - One of the most important test equipment in the biomedical workshop is the ECG Tester or Patient Simulator. The Patient Simulator is connected to the ECG monitor and delivers the typical ECG signal. Only with such a tester an ECG monitor can be repaired, the functions and alarm settings checked and loose connections of the patient cables be located. A Patient Simulators usually costs several hundred dollars and is unaffordable for small hospital workshop specially in developing countries. __ Designed by Frank Weithöner

DIY Lie Detectors - Makezine recently posted a diy lie detector kit that uses your skin resistance (aka sweat) to detect a lie. The kit is well explained and consists of two probes you place on your palm with a red/green led readout.

ECG Amplifier using TLC274 opamp - This circuit allows an ECG signal to be displayed on an oscilloscope. Opamps IC1a, b and d form an instrumentation amplifier with a gain of 201. IC1c amplifies the common-mode signal by a factor of 31, and supplies this signal to the right leg. The first consequence of this is that the body is brought to a defined common-mode level, so that the signal will not lie outside the range of the instrumentation amplifier.__ Learning Electronics

ECG Amplifier with right leg drive - Medical and health related electronic circuit diagrams / circuit schematics

Electronic Muscle Stimulation - This is an electronic muscle stimulator circuit that stimulates nerves of that part of your body where electrodes are attached. It is useful to relieve headache and muscle pain and revive frozen muscles that impair movement. It’s mainly muscle stimulation aid is removing cellulitis and build up you muscles. Can be used __ Designed by Popescu Marian

Electronic Stethescope Amplifier - The post explains how to make an electronic stethoscope amplifier circuit for enabling a loud audible reproduction of the heart beats which is being diagnosed. The article also reveals how the same can be applied within a cellphone through a wireless circuit

Electronic Stethoscope - Medical and health related electronic circuit diagrams / circuit schematics __ Designed by Aaron Cake

Medical Electronics Notes Pdf Format

Electronic Stethoscope - U1a operates as a low-noise microphone preamp. Its gain is only about 3.9 because the high output impedance of the drain of the FET inside the electret microphone causes U1a’s effective input resistor to be __ Designed by Audioguru

ESP SIM Sound Impairment Monitor - The smallest variation in amplifier performance is shown with this simple circuit __ Designed by Rod Elliott ESP

Fluid_Medical_Detector - A simple 40KHz 12v peak to peak square wave signal generator, using a 555 timer oscillator, was fed to the metal needle and the whole vertical indexing system, which was electrically isolated from everything else. On the receiver end, a copper foil electrode, which was designed to fit snugly on the bottom of a plastic cup, acted as a holder for the fluid container. . . . Dave Johnson, Lubbock TX-DC Magazine - Issue 11 July 2010

Galvanic Skin Response (GSR) - Medical and health related electronic circuit diagrams / circuit schematics

Medical Electronics Notes Pdf Examples

Guiding Visually Challenged using Raspberry Pi - Blindness is a state of lacking the visual perception due to physiological or neurological factors. Partial blindness represents the lack of integration in growth of the optic nerve or visual centre...__ Electronics Projects for You